Tcp Ipv6 Timer Fin-Timeout; Tcp Ipv6 Timer Syn-Timeout - 3Com S7906E Command Reference Manual

6300 series
Hide thumbs Also See for S7906E:
Table of Contents

Advertisement

Description
Use the reset udp ipv6 statistics command to clear the statistics of all IPv6 UDP packets.
Examples
# Clear the statistics of all IPv6 UDP packets.
<Sysname> reset udp ipv6 statistics

tcp ipv6 timer fin-timeout

Syntax
tcp ipv6 timer fin-timeout wait-time
undo tcp ipv6 timer fin-timeout
View
System view
Default Level
2: System level
Parameters
wait-time: Length of the finwait timer for IPv6 TCP connections in seconds, in the range of 76 to 3,600.
Description
Use the tcp ipv6 timer fin-timeout command to set the finwait timer for IPv6 TCP connections.
Use the undo tcp ipv6 timer fin-timeout command to restore the default.
By default, the length of the finwait timer is 675 seconds.
Examples
# Set the finwait timer length of IPv6 TCP connections to 800 seconds.
<Sysname> system-view
[Sysname] tcp ipv6 timer fin-timeout 800

tcp ipv6 timer syn-timeout

Syntax
tcp ipv6 timer syn-timeout wait-time
undo tcp ipv6 timer syn-timeout
View
System view
Default Level
2: System level