Use the undo oam errored-frame period command to restore the default.
By default, the errored frame detection interval is one second.
An error frame event occurs when a errored frame detection interval expires and the number of the
frame errors occurred on an Ethernet port is larger than (or equal to) the errored frame event triggering
threshold.
The errored frame detection interval applies to all the Ethernet ports on which OAM connections are
established.
Related commands: oam errored-frame threshold, display oam link-event, display oam
configuration.
Examples
# Set the errored frame detection interval to 10 seconds.
<Sysname> system-view
[Sysname] oam errored-frame period 10

oam errored-frame threshold

Syntax
oam errored-frame threshold threshold-value
undo oam errored-frame threshold
View
System view
Default Level
2: System level
Parameters
threshold-value: Errored frame event triggering threshold, ranging from 0 to 4294967295.
Description
Use the oam errored-frame threshold command to set the errored frame event triggering threshold.
Use the undo oam errored-frame threshold command to restore the default.
By default, the errored frame event triggering threshold is 1.
An errored frame event occurs when a errored frame detection interval expires and the number of the
frame errors occurred on an Ethernet port is larger than (or equal to) the errored frame event triggering
threshold.
The errored frame event triggering threshold configured applies to all the Ethernet ports on which
Ethernet OAM connections are established.
Related commands: oam errored-frame period, display oam link-event, display oam
configuration.
Examples
# Set the errored frame event triggering threshold to 100.
<Sysname> system-view
1-11