Alarm Oam Error-Symbol-Period Enable - 3Com S7906E Command Reference Manual

6300 series
Hide thumbs Also See for S7906E:
Table of Contents

Advertisement

When the upper limit and the lower limit of the alarm threshold are set to 0, large amount of alarms
are generated immediately. Since alarm events are carried in the OAM packets, large amount of
OAM packets are generated. In this case, OAM packets may be lost.
The commands here take effect only for OAM 2.0 and above.
Examples
# On ONU 1/0/1:1, set the higher window size, lower window size, higher alarm threshold, and lower
alarm threshold for the error symbol period alarm to 1, 3, 10, and 30 respectively.
<Sysname> system-view
[Sysname] interface onu 1/0/1:1
[Sysname-Onu1/0/1:1] alarm oam error-symbol-period window-high 1 window-low 3 threshold-high
10 threshold-low 30

alarm oam error-symbol-period enable

Syntax
alarm oam error-symbol-period enable
undo alarm oam error-symbol-period enable
View
OLT port view, ONU port view, FTTH view
Default Level
2: System level
Parameters
None
Description
Use the alarm oam error-symbol-period enable command to enable the error symbol period alarm.
Use the undo alarm oam error-symbol-period enable command to disable the error symbol period
alarm.
By default, the error symbol period alarm is enabled.
The commands here take effect only for OAM 2.0 and above.