Parameters
None
Description
Use the alarm oam error-frame enable command to enable the error frame alarm.
Use the undo alarm oam error-frame enable command to disable the error frame alarm.
By default, this function is enabled.
The commands here take effect only for OAM 2.0 and above.
Examples
# Enable the error frame alarm for the ONU corresponding to ONU 3/0/1:1.
<Sysname> system-view
[Sysname] interface onu 3/0/1:1
[Sysname-Onu3/0/1:1] alarm oam error-frame enable

alarm oam error-frame-seconds-summary

Syntax
alarm oam error-frame-seconds-summary { window window | threshold threshold } *
undo alarm oam error-frame-seconds-summary { window | threshold } *
View
OLT port view, ONU port view, FTTH view
Default Level
2: System level
Parameters
window window: Specifies the window size, in the range 100 to 9000 (in 100 ms). By default, the
window size is 600.
threshold threshold: Specifies the alarm threshold, in the range 1 to 900 (in seconds). By default, the
threshold is 1 second.
Description
Use the alarm oam error-frame-seconds-summary command to configure the corresponding
window size and alarm threshold.
Use the undo alarm oam error-frame-seconds-summary to restore the default window size and
alarm threshold.