5.
Disconnect PJ201 from the marking unit heater PWB and PJ801 from the marking unit
driver PWB,
Figure
4.
NOTE: A new marking unit heater PWB to solenoid patch PWB harness is supplied with a
new ink reservoir.
2
1
Disconnect PJ801 (see NOTE).
Disconnect PJ201.
Figure 4 Disconnect harness
ColorQube® 9303 Family
6.
Remove the ink reservoir,
3
Remove 2 screws, then lift the ink
reservoir to remove it.
February 2013
4-351
Figure
5.
1
2
Disconnect upper and
Disconnect PJ760 and
lower purge hoses.
PJ630 from the sole-
noid patch PWB.
Figure 5 Ink reservoir removal
Repairs/Adjustments
REP 91.20