3.
Disconnect the upper and lower umbilicals from the ink reservoir,
Figure 2 Umbilical removal
Repairs/Adjustments
REP 91.20
Figure
2.
4.
Remove the marking unit enclosure,
1
Remove 2 screws then
the umbilical clamp.
2
Disconnect the
umbilicals from the
ink reservoir.
3
Remove the gasket from
the ink reservoir or from
the umbilical.
2
Remove the enclosure.
February 2013
4-350
Figure
3.
1
Loosen 2 outer screws then remove
the middle screw.
Figure 3 Marking unit enclosure removal