Remove the support bracket and ejector assembly,
2
3
Remove the support
Remove the ejector assembly
bracket.
and wiring loom.
Figure 3 Remove the ejector assembly
Replacement
1.
Set the front and rear support fingers so that their ends are aligned when extended. See
REP
12.8-171.
2.
When reinstalling the eject assembly ensure that the tag on the ejector locates into the
slot in the frame.
Repairs/Adjustments
REP 12.6-171
Figure
3.
1
Remove 4 screws.
February 2013
4-132
3.
When refitting the pressing plate, the shaft of the front support finger drive gear must fit in
the ejector assembly, see
Figure
4. Replace the front pressing plate finger.
End of the gear
shaft.
Figure 4 Reinstalling the Pressing Plate
4.
The remainder of the replacement procedure is the reverse of the removal procedure.
5.
Locate the Mod/Tag plate on the metal panel under the HVF docking latch. Ensure that
Tag 004 is struck off.
Front pressing plate finger.
1
Move the cover to the front
to locate the shaft end.