Xerox ColorQube 9303 Series Service Manual page 946

Table of Contents

Advertisement

REP 12.50-171 BM Exit Sensor
Parts List on
PL
12.185.
Removal
Take care during this procedure. Sharp edges may be present that can cause injury.
Switch off the electricity to the machine
tomer supply while performing tasks that do not need electricity. Electricity can cause
death or injury. Moving parts can cause injury.
1.
Remove the BM right hand cover,
REP
2.
Remove the exit plate,
Figure
1.
1
Remove 4 screws to release the
exit plate.
Figure 1 Remove the exit plate
Repairs/Adjustments
REP 12.50-171
WARNING
WARNING
GP
14. Disconnect the power cord from the cus-
12.56-171.
3.
Figure
2, remove the BM exit sensor.
1
Remove the screw then
slide out the sensor.
Replacement
Reverse the removal procedure to replace the BM exit sensor.
February 2013
4-188
2
Disconnect
the harness
then remove
the sensor.
Figure 2 Sensor removal