REP 1.2 Molex SL Connectors

Removal
Switch off the electricity to the machine. Refer to
from the customer supply while performing tasks that do not need electricity. Electricity
can cause death or injury. Moving parts can cause injury.
NOTE: Molex connectors have small black housings in single and double row form with minia-
ture square section pins and sockets.
1.
If the damaged connector is in the centre of a double row housing beneath the latching
clip, the latching prong will not be accessible to release the connector from the housing.
Therefore it will be necessary to disassemble the housing as shown in
1
Hold the wires from both
row connectors
5
4
Pull out the A
Pull out the B row connector
row connector
Figure 1 Disassembling the connector.
Repairs/Adjustments
REP 1.2
WARNING
GP
14. Disconnect the power cord
Figure
2
Attach the Molex tool
3
Bend the housing open
2.
Figure
2. Remove the terminal from the connector housing using the Molex extractor tool.
1.
3
Push the terminal out of the
housing using a male terminal
from the repair kit
3.
Cut off the damaged terminal, then strip 3 mm of insulation from the end of the wire.
Replacement
1.
Select the correct replacement terminal, and identify the appropriate crimp positions for
the terminal.
2.
Figure
3. Insert a male or female terminal into the appropriate position of the crimp tool
and close the tool just enough to hold the terminal.
February 2013
4-6
1
Insert the Molex tool
2
Press the prong flat
Figure 2 Removing the terminal.