Xerox ColorQube 9303 Series Service Manual page 1394

Table of Contents

Advertisement

Option 5 Y Dot Position Correction
Umbilical Assembly (Original Head Reinstalled)
Refer to
PL 91.20 Item
10,
PL 91.25 Item
Perform the following procedures in the order shown:
1.
dC967
Head to Drum Spacing Check.
2.
dC971
Head to Head Alignment Adjustment.
3.
dC972
Printhead Uniformity:
Option 3 Head to Head Uniformity
Option 4 TRC Generation
Option 5 Y Dot Position Correction
Upper Carriage Assembly (Original Head Reinstalled)
Refer to
PL 91.20 Item
1.
Perform the following procedures in the order shown:
1.
dC967
Head to Drum Spacing Check.
2.
dC971
Head to Head Alignment Adjustment.
3.
dC972
Printhead Uniformity:
Option 3 Head to Head Uniformity
Option 4 TRC Generation
Option 5 Y Dot Position Correction
Lower Carriage Assembly (Original Head Reinstalled)
Refer to
PL 91.25 Item
1.
Perform the following procedures in the order shown:
1.
dC967
Head to Drum Spacing Check.
2.
dC971
Head to Head Alignment Adjustment.
3.
dC972
Printhead Uniformity:
Option 3 Head to Head Uniformity
Option 4 TRC Generation
Option 5 Y Dot Position Correction
X Axis Drive Motor
Refer to
PL 91.20 Item
5,
PL 91.25 Item
Perform
dC971
Head to Head Alignment Adjustment.
Stitch Roll Motor
Refer to
PL 91.20 Item
4,
PL 91.25 Item
Perform
dC971
Head to Head Alignment Adjustment.
Stitch Roll Motor Lead Screws
Refer to
PL 91.20 Item 21
and
PL 91.25 Item
Perform
dC971
Head to Head Alignment Adjustment.
General Procedures/Information
GP 37
10.
5.
4.
21.
Purge Line Filter
Refer to
PL 91.20 Item
9.
Perform
dC971
Head to Head Alignment Adjustment.
Reservoir
Refer to
PL 93.10 Item
10.
Perform the following procedures in the order shown:
1.
dC971
Head to Head Alignment Adjustment.
Drum
Refer to
PL 94.20 Item
1.
Perform the following procedures in the order shown:
1.
dC967
Head to Drum Spacing Check.
2.
dC971
Head to Head Alignment Adjustment.
3.
dC977
Drum Runout Calibration.
4.
dC625
Registration / Preheat Calibration.
5.
dC972
Printhead Uniformity. Select Options;
Option 3 Head to Head Uniformity - manual.
Option 4 TRC Generation.
Option 5 Y Dot Position Correction, select all 4 printheads.
Front Drum Frame Assembly
Refer to
PL 94.20 Item
16.
Perform the following procedures in the order shown:
1.
dC967
Head to Drum Spacing Check.
2.
dC971
Head to Head Alignment Adjustment.
3.
dC977
Drum Runout Calibration.
4.
dC972
Printhead Uniformity. Select Options;
Option 3 Head to Head Uniformity - manual.
Option 4 TRC Generation.
Option 5 Y Dot Position Correction, select all 4 printheads.
Drum Drive Motor
Refer to
PL 94.20 Item
6.
Perform
dC971
Head to Head Alignment Adjustment.
Drum Position Encoder
Refer to
PL 94.20 Item
8.
Perform the following procedures in the order shown:
1.
Perform
dC971
Head to Head Alignment Adjustment.
2.
Perform
dC977
Drum Runout Calibration.
February 2013
6-102
ColorQube® 9303 Family

Advertisement

Table of Contents
loading