Table 6 IOT NVM (IME) ID Range 489 to 499-xxx
NVM ID
NVM Name
NVM Description
489-003 PreheatTemp:
Temperature of pre-heater
Paper prints
when printing on paper
489-004 PreheatTemp:
Temperature of pre-heater
Transparency
when printing on transparency
prints
489-005 PreheatTemp:
Temperature of pre-heater
PaperPath clean-
when performing paper path
ing
cleaning
489-006 PreheatTemp: For
Temperature of pre-heater
jam in prehtr
when jam in pre-heater
489-007 PreheatTemp:
Temperature of pre-heater
Low pwr mode
when in low power mode
489-008 PreheatTemp:
Temperature of pre-heater
Sleep mode
when in sleep mode
490-001 IOD Sensitivity
Count of failures since last
fail count
success of IOD sensitivity
490-002 Sensitivity tool
Sensitivity tool State
State
490-003 IOD Sensitivity
Time stamp for last successful
pass timestamp
IOD sensitivity
490-004 IOD YDotPosi-
Count of failures since last
tionCorrect count
success of IOD YDotPosition-
Correct
490-005 YDotPositionCor-
YDotPositionCorrection tool
rection tool Stat
State
490-006 IOD YDot-
Time stamp for last successful
PosCorect pass
IOD IODYDotPostionCorrect
timestamp
490-007 IOD H2Uniformity
Count of failures since last
fail count
success of IOD H2HUniformity
General Procedures/Information
dC131
NVM ID
490-008 H2HUniformity
Settings
Default
Range = 0 to 2,000
610
Range = 0 to 2,000
610
Range = 0 to 2,000
850
490-009 IOD H2Uniformity
Range = 0 to 2,000
560
490-010 IOD DeltaTRC fal
Range = 0 to 2,000
500
490-011
Range = 0 to 2,000
0
Range = 0 to 255
0
Read: auto status
1
0 = optimal
490-012 IOD DeltaTRC
1 = non optimal
2 = disabled
490-019 H2HAlignAdjust
Write: control
3 = disabled auto
4 = enable auto
Range = 0 to 4
Range = 0 to
0
4,294,967,295
Range = 0 to 255
0
490-020 UTP index
Read: auto status
1
0 = optimal
490-021 UTP choice
1 = non optimal
2 = disabled
Write: control
3 = disabled auto
4 = enable auto
Range = 0 to 4
Range = 0 to
0
4,294,967,295
Range = 0 to 255
0
490-022 UTP Choice 3
February 2013
6-142
Table 6 IOT NVM (IME) ID Range 489 to 499-xxx
NVM Name
NVM Description
H2HUniformity tool State
tool State
Time stamp for last success of
pass timestamp
IOD H2HUniformity
Count of failures since last
count
success of IOD Delta TRC
TRC tool State
TRC tool State
Timestamp for last success of
pass timestamp
IOD Delta TRC
H2HAlignAdjust tool State
tool State
Index into selected uniformity
time out profile
Choice of uniformity time out
profiles
Uniformity Time out Profile 3,
Index 0 Day
index 0
Count
Settings
Default
Read: auto status
1
0 = optimal
1 = non optimal
2 = disabled
Write: control
3 = disabled auto
4 = enable auto
Range = 0 to 4
Range = 0 to
0
4,294,967,295
Range = 0 to 255
0
Read: auto status
0
0 = optimal
1 = non optimal
2 = disabled
Write: control
3 = disabled auto
4 = enable auto
Range = 0 to 4
Range = 0 to
0
4,294,967,295
Read: auto status
1
0 = optimal
1 = non optimal
2 = disabled
Write: control
3 = disabled auto
4 = enable auto
Range = 0 to 4
When changing pro-
0
file choice, set to 0
Range = 0 to 4
Profile 0:
1
14.28.56.0.0
Profile 1:
14.28.56.126.0
Profile 2:
28.56.112.0
Profile 3: program-
able in NVRAM
below
Range = 0 to 3
0 means end of list
0
Range = 0 to 255