3.
Re-install the harness guide plate. Ensure the harnesses are correctly positioned,
4.
Figure 4 Guide plate replacement
4.
Check that the image processor module opens and closes smoothly without trapping the
harnesses. If necessary, repeat replacement steps 2 and 3.
5.
If a new scanner module has been installed, perform the following:
a.
dC608
Document Feeder Registration.
b.
dC609
Document Glass Registration.
c.
Enter
dC131
NVM Read/Write. Make sure the following IIT DADH NVM settings are
set to default:
•
800-005
•
800-006
•
800-007
•
800-008
•
800-009
•
801-005
•
801-006
•
801-007
•
801-008
ColorQube® 9303 Family
Figure
1
Locate the rear
of the harness
guide plate in
the slot.
2
Install the guide plate as shown.
The scanner end of the harnesses
must be routed above guide plate.
The connector end must be
routed below the guide plate. Re-
install the 2 screws.
February 2013
4-245
•
801-009
•
801-010
•
801-011
•
801-012
•
801-013
•
801-014
•
801-015
•
801-016
•
801-017
•
801-018
•
801-019
•
801-020
•
801-021
•
801-022
•
801-023
•
801-024
•
801-025
•
801-026
Repairs/Adjustments