REP 12.90-171 Bottom Tray and Paper Sensors
Parts List on
PL
12.300.
Removal
Take care during this procedure. Sharp edges may be present that can cause injury.
Switch off the electricity to the machine. Refer to
from the customer supply while performing tasks that do not need electricity. Electricity
can cause death or injury. Moving parts can cause injury.
1.
Undock the Inserter,
REP
12.82-171.
Repairs/Adjustments
REP 12.90-171
WARNING
WARNING
GP
14. Disconnect the power cord
2.
Remove the bottom tray sensor bracket,
NOTE: Observe the position of the two springs when lifting the bottom tray.
3
Remove the pivot shaft
Paper present
sensor.
5
Remove the relevant
sensor
Figure 1 Bottom Tray and Sensors
Replacement
1.
Reverse the removal procedure to replace the bottom tray and paper sensors.
2.
Check that the loading levers are at the same angle and that the tray pivot shaft passes
below the front and rear loading levers. Check that the bottom tray is supported horizon-
tally in the frame.
3.
Make sure that the bottom tray springs are correctly aligned before engaging the front and
rear pivot tabs.
February 2013
4-232
Figure
1.
4
Remove 2 screws, then
1
the sensor bracket.
Release the front and rear pivot
tabs and lift the bottom tray.
ColorQube® 9303 Family
2
Remove the
circlip and
bearing.