Rep 70.1 3 Tray Module Pwb - Xerox ColorQube 9303 Series Service Manual

Table of Contents

Advertisement

REP 70.1 3 Tray Module PWB

Parts List on
PL 73.16
Removal
Switch off the electricity to the machine. Refer to
from the customer supply while performing tasks that do not need electricity. Electricity
can cause death or injury. Moving parts can cause injury.
Figure 1 ESD Symbol
Ensure that ESD procedures are observed during the removal and installation of the 3 tray
module PWB.
1.
Remove the (upper) rear cover,
PL 81.10 Item 1
8.
ColorQube® 9303 Family
WARNING
GP
14. Disconnect the power cord
CAUTION
and the (lower) rear cover,
2.
Remove the 3 tray module PWB,
PL 70.25 Item
Replacement
1.
Replacement is the reverse of the removal procedure.
2.
Perform
dC625
February 2013
4-261
Figure
2.
Figure 2 Remove the 3 tray module PWB
Registration / Preheat calibration.
1
Disconnect 8 PJs
2
Remove 7 screws