REP 91.1 Carriage Drive Train
Parts List on
PL 91.10
Removal
Switch off the electricity to the machine. Refer to
from the customer supply while performing tasks that do not need electricity. Electricity
can cause death or injury. Moving parts can cause injury.
Take care during this procedure. Sharp edges may be present that can cause injury.
1.
Slide out the marking unit to the maintenance position, Refer to
2.
Remove the marking unit enclosure,
2
Remove the marking unit
enclosure.
Figure 1 Enclosure removal
ColorQube® 9303 Family
WARNING
GP
14. Disconnect the power cord
WARNING
GP
6.
Figure
1.
1
Loosen 2 outer screws and
remove the middle screw.
3.
Disconnect the harnesses from the marking unit driver PWB,
February 2013
4-319
Figure
1
Disconnect PJ605 and PJ607.
Figure 2 Disconnect harnesses
2.
Repairs/Adjustments