When the AS MLC is out of the chassis, do not hold it by the ejector handles,
bus bars, or edge connectors. They cannot support its weight.
Do not stack AS MLCs on top of one another after removal. Place each
one individually in an electrostatic bag or on its own antistatic mat on a
flat, stable surface.
If necessary, remove each installed AS MSC and AS MXC from the AS MLC.
7.
After you remove each modular card, immediately place it on an antistatic mat or in
8.
an electrostatic bag.
If you are not reinstalling an AS MLC into the emptied slots within a short time, install
9.
a blank AS MLC panel over each slot to maintain proper airflow in the card cage.
CAUTION:
After removing an AS MLC from the chassis, wait at least 30
seconds before reinserting it or inserting an AS MLC into a different slot.

Figure 126: Removing an AS MLC

Preventing Electrostatic Discharge Damage to an MX240 Router on page 380