Juniper MX240 Hardware Manual page 318

5g universal routing platform
Hide thumbs Also See for MX240:
Table of Contents

Advertisement

MX240 5G Universal Routing Platform Hardware Guide
318
(2.8 Nm) of torque to each nut. Do not overtighten the nut. (Use a 7/16-in. [11 mm]
torque-controlled driver or socket wrench.)
a. Secure the positive (+) DC source power cable lug to the
b. Secure the negative (–) DC source power cable lug to the
CAUTION:
Ensure that each power cable lug seats flush against the surface
of the terminal block as you are tightening the nuts. Ensure that each nut
is properly threaded onto the terminal stud. The nut should be able to spin
freely with your fingers when it is first placed onto the terminal stud.
Applying installation torque to the nut when improperly threaded may
result in damage to the terminal stud.
CAUTION:
The maximum torque rating of the terminal studs on the DC
power supply is 36 lb-in. (4.0 Nm). The terminal studs may be damaged
if excessive torque is applied. Use only a torque-controlled driver or socket
wrench to tighten nuts on the DC power supply terminal studs.
CAUTION:
You must ensure that power connections maintain the proper
polarity. The power source cables might be labeled
their polarity. There is no standard color coding for DC power cables. The
color coding used by the external DC power source at your site determines
the color coding for the leads on the power cables that attach to the
terminal studs on each power supply.
NOTE:
The DC power supply in
power feeds derived from feed
be powered by dedicated power feeds derived from feed
configuration provides the commonly deployed
the system.
NOTE:
For information about connecting to DC power sources, see
Power Supply Electrical Specifications for the MX240 Router" on page
Replace the clear plastic cover over the terminal studs on the faceplate.
9.
Verify that the power cabling is correct, that the cables are not touching or blocking
10.
access to router components, and that they do not drape where people could trip on
them.
(return) terminal.
RTN
–48V
(input) terminal.
and
(+)
PEM0
must be powered by dedicated
, and the DC power supply in
A
A/B
feed redundancy for
Copyright © 2019, Juniper Networks, Inc.
to indicate
(–)
must
PEM2
. This
B
"DC
51.