4 System Startup and Sample Programs

4.1.8 Setting and Saving Communication Process (Communication Manager)

4.1.8 Setting and Saving Communication Process (Communication Manager)
Use the following procedure to set the communication process between the personal computer (MPE720) and the
MP2100 using the Communication Manager. These settings are not required if the communication settings have
already been made.
1. Open the YE_Applications folder and double-click the Communication Manager icon in the
YE_Applications folder. Or, Click Start - All Programs - YE_Applications - Communication Manager
to start the Communication Manager.
The Communication Process icon appears on the task tray at the bottom right of the window (version
5.30 or later).
2. Double-click the Communication Process icon in the task tray to open the Communication Manager
window shown in step 3.
3. Double-click number 1 in the Logical PT column in the Communication Manager window, to display
the Logical Port Setting window.
4-12
Communication Process Icon
Double-click