3. PERIODIC CHECK
3.5

Maintenance procedure

Caution:
• When replacing periodically replaced parts, be sure to unplug the power cord of the main body
from the power outlet.
3.5.1

External section

A. Replacing the ozone filters /A, /K and the conveyance suction filter
(1) Periodically replaced parts/cycle
• Ozone filter /A: Every 4,500,000 prints
• Ozone filter /K: Every 4,500,000 prints
• Conveyance suction filter: Every 4,500,000 prints
(2) Procedure
[1]
36
[1]
[2]
1050fs2053c
[2]
[3]
1050fs2054c
Field Service Ver3.0 Nov.2006
1.
Loosen 2 screws [1] and remove the exhaust
cover [2].
2.
Remove 2 ozone filters /A [1] and the ozone filter
/K [2], and the conveyance suction filter [3].
3.
Reinstall the above parts following the removal
steps in reverse.