5. FIRMWARE VERSION UP
(2) Preparations for transmission on the copier
1)
Checking of the ROM version
Before rewriting the ROM data, be sure to check the ROM version of the current control program by following
the procedure given below.
Step
1
Enter the service mode.
2
Press the [08 ROM version] key in "Service mode menu screen."
3
Press the [01 ROM version] key in the sub-menu displayed on the right side of the screen.
4
"ROM version screen"
Press the [08 ROM version] key and check the version information.
2)
Standby for the ISW transfer
Open the service mode of the copier and get into the standby of the ISW transmission.
Step
1
Enter the service mode.
2
Press the [10 ISW] key in "Service mode menu
screen."
3
Press the [01 ISW] key in the sub menu dis-
played on the right side of the screen.
4
[Service mode menu]
Example: Image control: collective
210
Operation
Operation
Field Service Ver3.0 Nov.2006
Remarks
The ISW standby status is a status in which the
[Start] key is shown in the display section.