Field Service Ver3.0 Nov.2006
3.5.3

Developing section

A. Replacing the suction filter
(1) Periodically replaced parts/cycle
• Suction filter: Every 750,000 prints
(2) Procedure
[2]
B. Replacing the developing suction assembly
(1) Periodically replaced parts/cycle
• Developing suction assembly: Every 6,000,000 prints
(2) Procedure
[1]
1.
Pull the photo conductor section out of the main
body.
(See P.38)
2.
Open the cover of the developing suction assem-
[1]
bly [1].
3.
Remove the suction filter [2].
4.
Clean the outside and the inside of the develop-
ing suction assembly with the cleaner.
NOTE
• When reinstalling the suction filter, be sure to
expand the filter opening before installation.
1050fs2107c
• When reinstalling it, make sure that the cover
of the developing suction assembly has been
closed thoroughly.
5.
Reinstall the above parts following the removal
steps in reverse.
1.
Pull the photo conductor section out of the main
body.
(See P.38)
2.
Remove the screw [1] and then remove the
developing suction assembly [2].
3.
Reinstall the above parts following the removal
[2]
steps in reverse.
1050fs2108c