Field Service Ver3.0 Nov.2006
(2) Procedure for reinstallation
[4]
[5]
1.
[3]
2.
NOTE
• Be sure to adjust the distance a [5] between
the thermistor /1 and the fusing roller /Up so
that it becomes equal to the thickness of the
[1]
temperature sensor positioning jig /A.
Specified value: a = 0.75 ± 0.1 mm
• Make sure that the thermistor /1 is parallel to
the roller.
3.
4.
[2]
1050fs2209c
Insert the temperature sensor positioning jig /A
[3] between the thermistor /1 [1] and the fusing
roller /Up [2].
Adjust the position of the thermistor /1 so that it
become flush with the temperature sensor posi-
tioning jig /A, and then fix it with the screw [4].
Apply Screw-lock to the screw [4].
For the parts to be reinstalled hereafter, reinstall
them following the removal steps in reverse.