Field Service Ver3.0 Nov.2006
G. Temperature adjustment
Sets the temperatures to be detected by the glue
apply roller temperature sensor (TH1), the glue tank
temperature sensor/Up (TH2), the glue tank tempera-
ture sensor/Md (TH3), and the glue tank temperature
sensor/Lw (TH4) provided in the glue tank.
(1) Procedure
1.
Enter the service mode.
2.
"Service mode menu screen"
Press the [11 Finisher Adjustment] key.
3.
A sub menu appears on the right side of the
screen.
Press the [07 Perfect Binder Adjustment] key
on the sub menu.
4.
"Perfect
Binder
screen"
Press the [07 Temperature Adjustment] key.
5.
"Temperature Adjustment screen"
Press the [COPY] key.
6.
Select the paper type and press the start but-
ton to make test prints and carry out perfect
binding.
7.
Check that the glue applied has dried appropri-
ately.
8.
To adjust the dryness of the glue, press the
[SERVICE] key.
9.
"Temperature Adjustment screen"
Press the [NEXT] or the [Back] key to select the
option of which the temperature is set.
The following options are provided.
Melt Tank - Top
Melt Tank - Mid
Melt Tank - Low
Pasting Roller
adjustment
mode
menu
10.
Enter a value through the numeric keys and
press the [Set] key.
• Melt Tank - Top
Setting range: 10 to 200 °C
Default: 132 °C
• Melt Tank - Mid
Setting range: 140 to 200 °C
Default: 145 °C
• Melt Tank - Low
Setting range: 140 to 200°C
Default: 185 °C
• Pasting Roller
Setting range: 140 to 200 °C
Default: 165 °C
11.
Repeat the steps 5 to 10 until an appropriate
value is obtained.
10. SERVICE MODE