Konica Minolta bizhub PRO 1050 Service Manual page 201

Hide thumbs Also See for bizhub PRO 1050:
Table of Contents

Advertisement

Field Service Ver3.0 Nov.2006
I.
Replacing the fusing heater lamp /3
NOTE
• Be careful not to touch the lamp section of the fusing heater lamp /3 with bare hands. When
touched, be sure to clean it with the roller cleaner.
(1) Periodically replaced parts/cycle
• Fusing heater lamp /3: Every 3,000,000 prints
(2) Procedure
[7]
[3]
[12]
[13][14]
1.
2.
[1]
3.
[2]
4.
5.
[8]
NOTE
• When attaching a new wiring band, be sure to
[9]
[10]
6.
[16]
7.
NOTE
• Be sure to fit in the fusing heater lamp /3 with
[15]
• When reinstalling the faston terminal, be sure
[17]
8.
[6]
NOTE
[5]
• When reinstalling the fixing plate /Rr, be sure
[4]
9.
[11]
1050fs2177c
NOTE
• When reinstalling the fixing plate /Fr, be sure
Pull out the ADU from the main
Remove the fusing section.
Open the fusing heating roller assembly.
(See P.165)
Cut off the wire binding band [1] and remove the
connector [2].
Cut off the wire binding band [3].
use a heat-resistant one.
Remove the screw [4] and then remove the wir-
ing harness clamp [5].
Remove the faston terminal [6].
the manufacturer's mark in this side.
to insert it securely.
Remove the screw [7] and then remove the fixing
plate /Rr [8].
to set the positioning hole [9] to the projection
[10] of the fusing heating roller assembly.
Remove the screw [11] and then remove the fix-
ing plate /Fr [12].
to set the positioning hole [13] to the projec-
tion [14] of the fusing heating roller assembly.
3. PERIODIC CHECK
body.(See P.112)
(See P.156)
169