Konica Minolta bizhub PRO 1050 Service Manual page 154

Hide thumbs Also See for bizhub PRO 1050:
Table of Contents

Advertisement

3. PERIODIC CHECK
I.
Replacing the transfer cleaning assembly/separation cleaning assemblies /1 and /2 and C-clips
(1) Periodically replaced parts/cycle
• Transfer cleaning assembly: Every 750,000 prints
• Separation cleaning assembly /1: Every 750,000 prints
• Separation cleaning assembly /2: Every 750,000 prints
• C-clip: Every 750,000 prints
(2) Procedure
[1]
122
[2]
[3]
[4]
[5]
[6]
1050fs2148c
Field Service Ver3.0 Nov.2006
1.
Pull out the ADU from the main body.
2.
Remove the transfer/separation charger unit.
(See P.116)
3.
Remove the discharge wire.
4.
Remove 3 C-clips [2] from the shaft [1] of each of
the cleaning assemblies.
5.
Turn over the transfer/separation charger unit [3]
and remove the transfer cleaning assembly [4]
and the separation cleaning assemblies /1 [5]
and /2 [6].
6.
Reinstall the above parts following the removal
steps in reverse.
(See P.112)