3. PERIODIC CHECK
R. Removing/reinstalling the thermistor /3
NOTE
• Be sure to make the position adjustments when the roller has cooled down.
• When reinstalling the thermistor /3, adjust it with the temperature sensor positioning jig /A before
fixing it. Be sure to apply Screw-lock to the screw that has been fixed.
• After completion of the reinstallation of the thermistor /3, be sure to check the wiring harness to
see if it is in touch with the fusing heating roller.
(1) Procedure for removal
[3]
[2]
186
1.
2.
3.
[6]
4.
NOTE
[1]
• When attaching a wire binding band, be sure
5.
6.
NOTE
• For the method for installing the thermistor /
7.
[4]
NOTE
• There are 4 connectors for the thermistor pro-
[5]
1050fs2210c
Field Service Ver3.0 Nov.2006
Pull out the ADU from the main body.
Remove the fusing section.
Open the fusing heating roller assembly.
(See
P.165))
Cut off 2 wiring bands [1].
to use a heat-resistant one.
Remove the screw [2] and then remove the 2 wir-
ing harness clamp [3].
Remove 2 screws [4] and then remove the ther-
mistor /3 [5].
3, see "(2) Procedure for reinstallation."
Remove the connector [6] of the thermistor /3.
vided at the same place and it is difficult to
identify
a
corresponding
advance. Therefore, the connector to be
removed can be identified by following the
wiring harness of the thermistor /3.
(See P.112)
(See P.156)
connector
in