Field Service Ver3.0 Nov.2006
(2) Procedure for reinstallation
[3]
1.
2.
NOTE
• Be sure to adjust the distance a [5] between
[4]
[1]
• Make sure that the thermistor /3 is parallel to
3.
4.
[5]
[2]
1050fs2211c
Insert the temperature sensor positioning jig /B
[3] between the thermistor /3 [1] and the fusing
heating roller [2].
Adjust the position of the thermistor /3 so that it
become flush with the temperature sensor posi-
tioning jig /B, and then fix it with 2 screws [4].
the thermistor /3 and the fusing heating roller
so that it becomes equal to the thickness of
the temperature sensor positioning jig /A.
Specified value: a = 0.7 ± 0.1 mm
the roller.
Apply Screw-lock to 2 screws [4].
For the parts to be reinstalled hereafter, reinstall
them following the removal steps in reverse.