3. PERIODIC CHECK
(3) Procedure (when equipped with the shaking mechanism)
174
2
1.
Pull out the ADU from the main
2.
Remove the fusing section.
3.
Open the fusing paper exit section.
4.
Remove the springs [1], one each, and then
remove 6 fusing claws /Up [2].
5.
Reinstall the above parts following the removal
steps in reverse.
[2]
[1]
1050fs2920c
Field Service Ver3.0 Nov.2006
body.(See P.112)
(See P.156)
(See P.158)