Konica Minolta bizhub PRO 1050 Service Manual page 192

Hide thumbs Also See for bizhub PRO 1050:
Table of Contents

Advertisement

3. PERIODIC CHECK
[7]
[4]
[5]
160
[1]
[2]
[6]
[5]
[3]
[2]
1050fs2407c
Field Service Ver3.0 Nov.2006
7.
Remove 2 faston terminals [2] of the fusing
heater lamp /2 [1].
NOTE
• When reinstalling the fusing heater lamp /2,
be sure to insert it securely while taking note
of the position in which the faston terminal is
installed.
8.
Remove 2 screws [3] and then remove the lamp
fixing plate /Fr [4].
9.
Pull out and remove each of the fusing heater
lamps in the arrow-marked direction [5].
NOTE
• When reinstalling each of the fusing heater
lamps, check to see if either end of each lamp
is set in the fitting holes of the lamp fixing
plates /Fr [4] and /Rr [6].
• After each of the fusing heater lamps is
installed, check to see if it is in touch with the
inner face of the fusing roller /Up [7].
10.
Reinstall the above parts following the removal
steps in reverse.