Field Service Ver3.0 Nov.2006
[3]
[2]
[1]
[4]
[4]
[4]
[1]
[1]
[4]
1050fs2024c
[3]
[2]
1050fs2025c
10.
Connect the connector [2] of the relay wiring har-
ness [1] to the CN599 of the ADU drive board /1
[3].
11.
Pull around the relay wiring harness [1] as shown
in the drawing and hold it with the relay wiring
clamps [4] provided at the 12 placed.
12.
Reinstall the transfer/separation charger unit [1].
13.
Connect the size detection connector [4] to the
connector [3] of the relay wiring harness [2].
14.
Reinstall the ADU covers /Rt and /Lt and the
lever A.
15.
Put the ADU back to the inside of the main body.
16.
Change the software DIPSW settings in the ser-
vice mode to the following.
• DIPSW26-0: On (1)
• DIPSW26-1: On (1)
NOTE
• When the above software DIPSW is changed,
the size detection connector is required by
the transfer/separation charger of standard
size. When the size detection connector is not
installed, the transfer assist sheet does not
operate.
6. OTHERS
309