11. MECHANICAL ADJUSTMENT
[1]
[5]
[3]
A
506
[2]
[6]
[4]
1050fs3037c
Field Service Ver3.0 Nov.2006
7.
Pull the plunger [2] of the pick-up solenoid [1] to
measure the gap "A" between the pick-up roller
[3] and the paper lift plate [4] with the gap gauge.
Standard value A = 0.1 to 1.5 mm
If it is not within the standard value, follow step 8
and after.
8.
Loosen the screw [5].
Note
• Before loosening the screw [5], record the
position of the pick-up solenoid [1] with the
marking line [6].
9.
With the plunger [2] pulled, adjust the position of
the pick-up solenoid [1] so that the standard value
can be obtained for the gap A between the pick-
up roller [3] and the paper lift plate [4].
10.
Tighten the screw [5] to fix the pick-up solenoid
[1].
11.
Replace the stopper of step 4 to the original posi-
tion.
12.
Insert a paper, and set the tray.
13.
Perform copying/printing to confirm that the no
feed does not occur.
14.
Reinstall the above parts following the removal
steps in reverse.
Note
• After the adjustment, be sure to replace the
stopper of the release lever to the original
position.