3. PERIODIC CHECK
G. Replacing the drum temperature sensor
(1) Periodically replaced parts/cycle
• Drum temperature sensor: Every 3,000,000 prints
(2) Procedure
[2]
46
[2]
[3]
[1]
[1]
1050fs2097c
Field Service Ver3.0 Nov.2006
1.
Pull out the photo conductor
2.
Remove the charger unit.
3.
Remove 2 connectors [1] and then remove the
wiring harness from the wiring harness clamp.
NOTE
• Take note of the direction of the connector to
be removed.
4.
Loosen 2 screws [2] and remove the sensor sup-
port stay assembly [3].
section.(See P.38)