Konica Minolta bizhub PRO 1050 Service Manual page 210

Hide thumbs Also See for bizhub PRO 1050:
Table of Contents

Advertisement

3. PERIODIC CHECK
N. Replacing the thermistor /2
Caution:
• After completion of the installation of the thermistor /2, be sure to check to see if it is in touch with
the fusing roller /Up.
(1) Periodically replaced parts/cycle
• Thermistor /2: Every 3,000,000 prints
(2) Procedure
[1]
178
[2]
[3]
[2]
1050fs2185c
Field Service Ver3.0 Nov.2006
1.
Open the front doors /Rt and /Lt, and pull out the
ADU from the main
body.(See P.112)
2.
Remove the fusing section.
3.
Open the fusing paper exit section [1].
4.
Insert the driver [4] into the hole [3] of the shaft [2]
and rotate the shaft [2] clockwise to release pres-
sure.
NOTE
• Not releasing pressure may cause damage to
the fusing heater lamp. Be sure to release it.
• When reinstalling it, be sure to rotate the shaft
[2] counterclockwise to apply pressure.
5.
Remove the connector [5].
6.
Remove 4 screws [6] and 2 stepped screws [7],
and then remove the web unit [8].
NOTE
• When attaching the stepped screw [7], make
sure that it gets in securely up to the step of
the screw.
• Be sure to remove the web section with it
closed. If the web is removed with it open, the
web section becomes unstable and you may
get injured.
(See P.156)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bizhub pro 1050eBizhub pro 1050epBizhub pro 1050p

Table of Contents