Field Service Ver3.0 Nov.2006
Step
6
Place the copier main body in the standby for the ISW transfer. (For the procedure, see "2) Standby
for the ISW transfer.")
7
Press the [Start] key on the copier main body side first, and then press the [File Send] key of the
ISWTrns.
8
The following window is displayed on the PC while in the data transfer.
9
When the data transfer is completed, the following window is displayed.
[PC side]
[Copier side]
10
When transmitting other data, press the [Yes] key.
When exiting the rewrite, press the [No] key.
When pressing the [No] key, the copier main body is automatically rebooted.
11
Check the ROM version information in the service mode to see if the rewrite operation is completed
normally.
It is not completed normally, repeat the procedure from the step 2.
Operations
5. FIRMWARE VERSION UP
221