7.10 Linear encoder position adjustment
< Verification procedure >
1.
Remove the COVER(SIDE-R)-MW (see
6.3.7).
2.
Open the caps manually (see 6.10.1).
3.
Move the carriage manually to the
maintenance area.
4.
Remove the following parts.
- COVER(SIDE-L)-MW (see 6.3.6)
- COVER(Y-RAIL)-SL-MW (see 6.3.3)
- COVER(Y-RAIL)-SR-MW (see 6.3.3)
- COVER(L)ASSY-MW (see 6.3.2)
- COVER(R)ASSY-MW (see 6.3.2)
OKI Data Infotech Corporation CONFIDENTIAL
COVER(L)ASSY-MW
COVER(R)ASSY-MW
COVER(SIDE-L)-MW
Chapter 7 Adjustment
COVER(Y-RAIL)-SL-MW
COVER(Y-RAIL)-SR-MW
7-39