Oki IP-6620 Maintenance Manual page 254

Solvent ink color inkjet printer
Hide thumbs Also See for IP-6620:
Table of Contents

Advertisement

5.5.20 System Error 190x: Power Supply Unit Error
<Description>
Voltage errors are detected when the following power voltages are checked.
X
0
PCB-ASSY-ACT3
1
PCB-ASSY-ACT3
2
PCB-ASSY-ACT3
3
PCB-ASSY-ACT3
5
PCB-ASSY-ACT3
6
PCB-ASSY-ACT3
7
PCB-ASSY-ACT3
8
PCB-ASSY-IPB5-100
9
PCB-ASSY-IPB5-100
A
PCB-ASSY-ACT3
* For the details of the power supplies' relationship, see the Appendix 3 Power Supply Schematic Diagram.
<Faulty part>
(1) PCB-ASSY-ACT3
(2) PCB-ASSY-IPB5-100
(3) Power supply unit (24V) (PSU 24V): POWER SUPPLY 24V, MW
(4) Window sensor OKI Data Infotech (interlock switch)
(5) Power supply unit (38V) (PSU 38V): POWER SUPPLY 36V, MW
Note:
If the PSU 38V output is cut, the power of the CPU and the peripheral circuits is also cut on the
PCB-ASSY-IPB5-100, preventing this error from occurring. Therefore the error 190X is rarely caused by
a PSU 38V problem.
Chapter 5 Troubleshooting (Engine Section and USB Controller Section)
Board
Power name
P12V
P24V
P24VAR
P24VSF
P38V
P38VAR
P38VAF
P38VAF
P38VCRG
P38ARHCB
OKI Data Infotech Corporation CONFIDENTIAL
Power supply
system
PSU38V  ACT3
PSU24V  ACT3
PSU24V  ACT3
The power is cut by the interlock
PSU38V  ACT3
PSU38V  ACT3
PSU38V  ACT3
The power is cut by the interlock
PSU38V  ACT3
PSU38V  ACT3 
IPB5
PSU38V  ACT3 
The power is cut by the interlock
IPB5
PSU38V  ACT3 
The power is cut by the interlock
HCB1M
Reference
5-95

Hide quick links: