6.6.2
FAN(EL UNIT) ASSY MW (POWER-BOX)
<Removal>
1.
Before starting the procedure, be sure to
disconnect the power cord from the
outlet.
2.
Open the POWER-BOX (see 6.6).
3.
Remove the harness from the clamp and
disconnect the connector.
4.
Remove the FAN(EL UNIT)ASSY MW
with two fixing screws.
Notes for installation
Orient the fans so that:
- The air flows from the inside to the outside of the printer; and
- The nameplate faces the outside of the printer.
Be careful not to catch the wires between the metal plates and the boards when closing the
POWER-BOX-COVER-F (see 6.6 for details on the position).
OKI Data Infotech Corporation CONFIDENTIAL
Chapter 6 Parts Replacement (Disassembly/Reassembly)
Clamp
Connector
FAN(EL UNIT)ASSY MW
6-47