Oki IP-6620 Maintenance Manual page 192

Solvent ink color inkjet printer
Hide thumbs Also See for IP-6620:
Table of Contents

Advertisement

REPLACE
WASTE INK BOTTLE
<Description>
Possible causes are as follows.
- The waste ink bottle is full.
- The sensor for checking the waste ink bottle is defective.
- The harness, connectors, or boards connected to the sensor above are defective.
<Action>
Check the Items to be Checked on the table below, and perform the actions starting from the top
until the problem is solved.
No
Items to be Checked
1
Waste ink bottle replacement
2
Waste ink bottle sensor (see 6.11.2
MICRO SWITCH 4(WASTE INK
BOTTLE ASSY))
Waste ink bottle sensor's connector
3
4
Connection of the CN22 connector on
PCB-ASSY-ACT3
5
Connection of the
CABLE(TU-SENS1)-ASSY(MW) and
CABLE(TU-SENS2)-ASSY(MW) cables.
6
PCB-ASSY-ACT3
7
PCB-ASSY-IPB5-100
OKI Data Infotech Corporation CONFIDENTIAL
Chapter 5 Troubleshooting (Engine Section and USB Controller Section)
Replace the waste ink bottle following the instruction in
the message displayed.
Check that the waste ink bottle is fixed securely. Then
on the operation panel's MONITOR menu, select
WASTE BOTTLE and set INSTALLED.
Check that the switch operation is correct.
Remove the connector, and then re-connect it.
Then on the operation panel's MONITOR menu, select
WASTE BOTTLE and set INSTALLED.
Check that the switch operation is correct.
Remove the connector, and then re-connect it.
Then on the operation panel's MONITOR menu, select
WASTE BOTTLE and set INSTALLED.
Check that the switch operation is correct.
Remove the connectors, and then re-connect them.
Then on the operation panel's MONITOR menu, select
WASTE BOTTLE and set INSTALLED.
Check that the switch operation is correct.
Replace the PCB-ASSY-ACT3 board. Then on the
operation panel's MONITOR menu, select WASTE
BOTTLE and set INSTALLED.
Check that the switch operation is correct.
Replace the PCB-ASSY-IPB5-100 board. Then on the
operation panel's MONITOR menu, select WASTE
BOTTLE and set INSTALLED.
Check that the switch operation is correct.
Action