5.3.2

Waste ink bottle related messages

INSTALL
WASTE INK BOTTLE
<Description>
Possible causes are as follows.
- No waste ink bottle is installed to the printer.
- The sensor for checking the waste ink bottle is defective.
- The harness, connectors, or boards connected to the sensor above are defective.
<Action>
Check the Items to be Checked on the table below, and perform the actions starting from the top
until the problem is solved.
No
1
A waste ink bottle is installed
2
Waste ink bottle sensor (see 6.11.2
MICRO SWITCH 4(WASTE INK
BOTTLE ASSY))
Waste ink bottle sensor's connector
3
4
Connection of the CN22 connector
on PCB-ASSY-ACT3
5
Connection of the
CABLE(TU-SENS1)-ASSY(MW)
and
CABLE(TU-SENS2)-ASSY(MW)
cables.
6
PCB-ASSY-ACT3
7
PCB-ASSY-IPB5-100
5-32
Chapter 5 Troubleshooting (Engine Section and USB Controller Section)
Items to be Checked
OKI Data Infotech Corporation CONFIDENTIAL
Action
If no waste ink bottle is installed, install it.
Check that the waste ink bottle is fixed securely. Then on
the operation panel's MONITOR menu, select WASTE
BOTTLE and set INSTALLED.
Check that the switch operation is correct.
Remove the connector, and then re-connect it.
Then on the operation panel's MONITOR menu, select
WASTE BOTTLE and set INSTALLED.
Check that the switch operation is correct.
Remove the connector, and then re-connect it.
Then on the operation panel's MONITOR menu, select
WASTE BOTTLE and set INSTALLED.
Check that the switch operation is correct.
Remove the connectors, and then re-connect them. Then
on the operation panel's MONITOR menu, select WASTE
BOTTLE and set INSTALLED.
Check that the switch operation is correct.
Replace the PCB-ASSY-ACT3 board. Then on the
operation panel's MONITOR menu, select WASTE
BOTTLE and set INSTALLED.
Check that the switch operation is correct.
Replace the PCB-ASSY-IPB5-100 board. Then on the
operation panel's MONITOR menu, select WASTE
BOTTLE and set INSTALLED.
Check that the switch operation is correct.