6.12.6 SUPPLY-PUMP-TUBE-ASSY
<Removal>
1.
Remove the SUPPLYPUMP-UNIT(MW)
(see 6.12.5).
2.
Remove the three screws securing the
FRAME(PUMP64) from the
SUPPLYPUMP-UNIT(MW), and remove
the SUPPLY-PUMP-TUBE-ASSY and
the other parts.
3.
Remove the ROLLER(PUMP), and
remove the
SUPPLY-PUMP-TUBE-ASSY.
Notes
Do not remove the grease from the tubes.
Reset the operating time counter of the
supply pump when you have replaced it.
When installing the pump, place the tube
around the FRAME(PUMP64) without
changing the natural bending of the tube or
twisting it.
Pay attention to the orientation of the joint.
OKI Data Infotech Corporation CONFIDENTIAL
Chapter 6 Parts Replacement (Disassembly/Reassembly)
FRAME(PUMP64)
ROLLER(PUMP)
SUPPLY-PUMP-TUBE-ASSY
6-113