MANUALLY CONFIGURE
NOZZLE MAPPING
<Description>
There was a problem with light intensity of PCB-ASSY-ADJ1 sensor during nozzle map automatic
configuration.
1. Calibration lower limit error: The light intensity of the sensor is below the lower limit.
2. Calibration higher limit error: The light intensity of the sensor is above the higher limit.
<Action>
Check the Items to be Checked on the table below, and perform the actions starting from the top
until the problem is solved.
No
Items to be Checked
Firmware
1
The media
2
Restart the printer with the media
3
installed and check that POC is
skipped.
Dirt on the PCB-ASSY-ADJ1
4
sensor surface
The connection of the
5
PCB-ASSY-ADJ1 harness
connectors
The PCB-ASSY-ADJ1 harness
6
condition
PCB-ASSY-ADJ1
7
PCB-ASSY-HCB1M
8
OKI Data Infotech Corporation CONFIDENTIAL
Chapter 5 Troubleshooting (Engine Section and USB Controller Section)
nn
nn: 1 Calibration lower limit error
Upgrade the firmware to the latest version.
Try with a different media.
If POC is not skipped, the problem is not with the media but
probably with the PCB-ASSY-ADJ1 path. Perform the
following solutions in the given order.
If soiled, clean the sensor surface with a soft cloth.
Check that the harness connectors are properly connected
to the board connectors.
- Check that the cables are not disconnected, caught in
order parts, and that the jackets are not damaged.
- Check that the AUTO ADJFFC,MW terminal is not
damaged.
- If a problem is found, replace the part.
Replace the PCB-ASSY-ADJ1.
Replace the PCB-ASSY-HCB1M.
2 Calibration higher limit error
Action
5-47