6.3.12 SWITCH(Interlock)-ASSY and SWITCH(COVER)-ASSY
<Removal>
1.
Open the COVER(FRONT)ASSY-MW,
and remove the following:
- COVER(SENSOR-L)-MW or
COVER(SENSOR-R)-MW; and
- One fixing screw
2.
Disconnect the connector connecting the
SWITCH(Interlock)-ASSY cable with the
SWITCH(COVER)-ASSY cable, and
remove the cables from the three clamps
(one on the left side and two on the right
side).
OKI Data Infotech Corporation CONFIDENTIAL
Chapter 6 Parts Replacement (Disassembly/Reassembly)
Left side
Connector
Right side
Connector
COVER(SENSOR-L)-MW
COVER(SENSOR-R)-MW
Cable clamp
Cable clamp