5.5.6
System Error 1320: Data Transfer Error from FPGA-RSM to FPGA-PTG
<Description>
Connection failed with the carriage cable (FFC) connected to the PCB-ASSY-IPB5-100.
This error is detected through the process below:
(1) The printer is started; and
(2) The write test from the PCB-ASSY-IPB5-100(RSM) to the PCB-ASSY-HCB1M(PTG)
fails.
<Faulty part>
(1) PCB-ASSY-HCB1M
(2) PCB-ASSY-IPB5-100
(3) Carriage cable (FFC): CARRIAGE FFC, MW
<Action>
Check the Items to be Checked on the table below, and perform the actions starting from the top
until the problem is solved.
No
1
The Plate-Fix(FFC) metal plate fixed
on the FFC's PCB-ASSY-HCB1M
2
FFC's connector connection
3
The width of the V-shaped folded
part on the PCB-ASSY-HCB1M-side
FFC
FFC's external damage
4
5
PCB-ASSY-HCB1M
6
PCB-ASSY-IPB5-100
7
FFC
Chapter 5 Troubleshooting (Engine Section and USB Controller Section)
Items to be Checked
OKI Data Infotech Corporation CONFIDENTIAL
Action
Check that the screws are tightened.
Reconnect the FFC on both the PCB-ASSY-HCB1M side
and the PCB-ASSY-IPB5-100 side.
If the cable terminals are smeared, softly wipe them with a
soft cloth or lint-free paper dampened with ethanol before
connecting them.
Check that the width of the V-shaped folded part on the
FFC is proper. If not, adjust it. For the adjustment
procedure, see 6.8.4 PCB-ASSY-HCB1M.
Check the following to ensure that the FFC is not
damaged.
- FFC's terminal is detached from its base.
- FFC's edges have not been abraded by friction.
If the FFC is damaged, replace it.
Replace the PCB-ASSY-HCB1M.
Replace the PCB-ASSY-IPB5-100.
Replace all four FFCs.