Oki IP-6620 Maintenance Manual page 180

Solvent ink color inkjet printer
Hide thumbs Also See for IP-6620:
Table of Contents

Advertisement

Panel Message
PH TEMP IS TOO HIGH
PRINT? OK/CANCEL
COOLING PRINT HEADS
XXXX CC nn
XXXX: Print mode
cc: Print density
nn: Print direction
<Communication-related errors>
Panel Message
NO DATA RECEIVED
CHECK CONNECTION
DATA COMMUNICATION
WAS INTERRUPTED
<Other errors>
Panel Message
CLOSE COVERS
PLEASE WARM THE ROOM
AND WAIT FOR A WHILE
ROOM TEMP TOO HIGH
PRINT? OK/CANCEL
DECREASE ROOM TEMP
XXXX CC nn
XXXX: Print mode
cc: Print density
nn: Print direction
Chapter 5 Troubleshooting (Engine Section and USB Controller Section)
Error Description
User Solution
The print heads
- Restart the printer.
temperature is not
- Check the ambient
within the operating
temperature.
range (high
temperature).
The monitored
- Restart the printer.
temperature of the
- Check the ambient
print heads exceeded
temperature.
40°C.
Error Description
User Solution
An error has been
- Replace the USB
detected in the USB
cable.
connection during print
- Restart the printer
data transfer.
and the computer.
A timeout error has
- Replace the USB
occurred during print
cable.
data transfer.
- Restart the printer
and the computer.
Error Description
User Solution
The front cover is
- Close the front
open.
cover.
- Restart the printer.
The ambient
- Restart the printer.
temperature is not
- Check the ambient
within the printer
temperature.
operating range (low
temperature).
The ambient
- Restart the printer.
temperature is not
- Check the ambient
within the printer
temperature.
operating range (high
temperature).
The ambient
- Restart the printer.
temperature is not
- Check the ambient
within the printer
temperature.
operating range (high
temperature).
OKI Data Infotech Corporation CONFIDENTIAL
Service Engineer Inspection
(For inspection criteria, see
Reference to Check/Replace
Parts.)
- Check the COOLINGFAN,MW
operation in the ACTUATORS
menu.
- Check that the COOLING
FAN,MW connectors are
connected correctly.
- Check that the CARRIAGE
FFC,MW connectors are
connected correctly to both the
HCB1M and the IPB5.
- Check that the HEAD
CABLE,MW connectors are
connected correctly.
- Check the COOLINGFAN,MW
operation in the ACTUATORS
menu.
- Check that the COOLING
FAN,MW connectors are
connected correctly.
- Check that the CARRIAGE
FFC,MW connectors are
connected correctly to both the
HCB1M and the IPB5.
- Check that the HEAD
CABLE,MW connectors are
connected correctly.
Service Engineer Inspection
(For inspection criteria, see
Reference to Check/Replace
Parts.)
Install the last firmware version.
Install the last firmware version.
Service Engineer Inspection
(For inspection criteria, see
Reference to Check/Replace
Parts.)
Check that the interlock switch
connectors are connected
correctly.
- Install the last firmware version.
- Check that the ambient
temperature thermistor cable is
not damaged or broken, and that
it is connected correctly.
- Install the last firmware version.
- Check that the ambient
temperature thermistor cable is
not damaged or broken, and that
it is connected correctly.
- Install the last firmware version.
- Check that the ambient
temperature thermistor cable is
not damaged or broken, and that
it is connected correctly.
Reference to
Assumed
Check/Replace
Replacement Part
Parts
- COOLING FAN,MW
- PCB-ASSY-HCB1M
- CARRIAGE FFC,MW
- HEAD CABLE,MW
- COOLING FAN,MW
- PCB-ASSY-HCB1M
- CARRIAGE FFC,MW
- HEAD CABLE,MW
Reference to
Assumed
Check/Replace
Replacement Part
Parts
- Firmware version
- PCB-ASSY-IPB5-100
- Firmware version
- PCB-ASSY-IPB5-100
Reference to
Assumed
Check/Replace
Replacement Part
Parts
- Window sensor OKI
Data Infotech
- PCB-ASSY-ACT3
- Firmware version
- Ambient temperature
thermistor
- PCB-ASSY-ACT3
- PCB-ASSY-IPB5-100
- Firmware version
- Ambient temperature
thermistor
- PCB-ASSY-ACT3
- PCB-ASSY-IPB5-100
- Firmware version
- Ambient temperature
thermistor
- PCB-ASSY-ACT3
- PCB-ASSY-IPB5-100
5-21

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents