6.4.6
ROBOT CABLE, MW
The ROBOT CABLE, MW is made of two different harnesses below:
- At the bottom of the printer (PCB-ASSY-ACT3 board side):
CABLE(Board-Power)-ASSY(MW)
- At the top of the printer (PCB-ASSY-HCB1M board side):
CABLE(ACT-HCB)1-ASSY(HV104)
Only the CABLE(ACT-HCB)1-ASSY(HV104) uses the robot cable..
<Removal>
1.
Before starting theprocedure, be sure to
disconnect the power cord from the
outlet.
2.
Remove the following parts.
- COVER(Y-RAIL)-SR-MW (see 6.3.3)
- COVER(Y-RAIL)-SL-MW (see 6.3.3)
- COVER(Y-RAIL)-64-MW (see 6.3.4)
3.
Open the controller box and remove the
CABLE(Board-Power)-ASSY(MW)
harness from the PCB-ASSY-ACT3. As
the harness is also connected to the
PCB-ASSY-IPB5-100, remove the board,
too.
Note that totally nine clamps at the
red-circled positions must be removed.
6-28
CABLE(Board-Power)-ASSY(MW)
OKI Data Infotech Corporation CONFIDENTIAL
Chapter 6 Parts Replacement (Disassembly/Reassembly)
COVER(Y-RAIL)-SR-MW
PCB-ASSY-ACT3
PCB-ASSY-IPB5-100
COVER(Y-RAIL)-SL-MW
COVER(Y-RAIL)-64-MW