Oki IP-6620 Maintenance Manual page 235

Solvent ink color inkjet printer
Hide thumbs Also See for IP-6620:
Table of Contents

Advertisement

Error
Cause
No.
3600
Head Heater Error (High
Temperature) (No.1)
3601
Head Heater Error (High
Temperature) (No.2)
3602
Head Heater Error (High
Temperature) (No.3)
3603
Head Heater Error (High
Temperature) (No.4)
3604
Head Heater Error (High
Temperature) (No.5)
3605
Head Heater Error (High
Temperature) (No.6)
3606
Head Heater Error (High
Temperature) (No.7)
3610
Head Heater Error (Target
Temperature Not Reached)
(No.1)
3611
Head Heater Error (Target
Temperature Not Reached)
(No.2)
3612
Head Heater Error (Target
Temperature Not Reached)
(No.3)
3613
Head Heater Error (Target
Temperature Not Reached)
(No.4)
3614
Head Heater Error (Target
Temperature Not Reached)
(No.5)
3615
Head Heater Error (Target
Temperature Not Reached)
(No.6)
3616
Head Heater Error (Target
Temperature Not Reached)
(No.7)
5-76
Chapter 5 Troubleshooting (Engine Section and USB Controller Section)
Service Engineer Inspection
(For inspection criteria, see
User Solution
Reference to Check/Replace
- Restart the printer.
- Check that the ambient
- Check the ambient
temperature at the installation
temperature.
location meets the operating
conditions (less than 35 degrees).
- Check that COOLING FAN,MW is
operating in the ACTUATORS
menu.
- Check the connection of COOLING
FAN,MW connectors.
- Check the connection of HEAD
CABLE,MW connectors on the
HCB1M and the print heads.
- Check the connection of
CARRIAGE FFC,MW connectors
on the HCB1M and the IPB5.
- Check the connection of ROBOT
CABLE,MW connectors.
- Restart the printer.
ditto
- Check the ambient
temperature.
- Restart the printer.
ditto
- Check the ambient
temperature.
- Restart the printer.
ditto
- Check the ambient
temperature.
- Restart the printer.
ditto
- Check the ambient
temperature.
- Restart the printer.
ditto
- Check the ambient
temperature.
- Restart the printer.
ditto
- Check the ambient
temperature.
- Restart the printer.
- Check that the ambient
- Check the ambient
temperature at the installation
temperature.
location meets the operating
conditions (more than 15 degrees).
- Check the connection of HEAD
CABLE,MW connectors on the
HCB1M and the print heads.
- Check the connection of
CARRIAGE FFC,MW connectors
on the HCB1M and the IPB5.
- Check the connection of ROBOT
CABLE,MW connectors.
- Restart the printer.
ditto
- Check the ambient
temperature.
- Restart the printer.
ditto
- Check the ambient
temperature.
- Restart the printer.
ditto
- Check the ambient
temperature.
- Restart the printer.
- Check that the ambient
- Check the ambient
temperature at the installation
temperature.
location meets the operating
conditions (more than 15 degrees).
- Check the connection of HEAD
CABLE,MW connectors on the
HCB1M and the print heads.
- Check the connection of
CARRIAGE FFC,MW connectors
on the HCB1M and the IPB5.
- Check the connection of ROBOT
CABLE,MW connectors.
- Restart the printer.
ditto
- Check the ambient
temperature.
- Restart the printer.
ditto
- Check the ambient
temperature.
OKI Data Infotech Corporation CONFIDENTIAL
Assumed Replacement
Parts.)
- COOLING FAN,MW
- HEAD CABLE,MW
- INKJET HEAD,MW
- ROBOT CABLE,MW
- CARRIAGE FFC,MW
- PCB-ASSY-HCB1M
- PCB-ASSY-IPB5-100
- ROBOT CABLE,MW
- CARRIAGE FFC,MW
ditto
ditto
ditto
ditto
ditto
ditto
- HEAD CABLE,MW
- INKJET HEAD,MW
- ROBOT CABLE,MW
- CARRIAGE FFC,MW
- PCB-ASSY-HCB1M
- PCB-ASSY-IPB5-100
- ROBOT CABLE,MW
- CARRIAGE FFC,MW
ditto
ditto
ditto
- HEAD CABLE,MW
- INKJET HEAD,MW
- ROBOT CABLE,MW
- CARRIAGE FFC,MW
- PCB-ASSY-HCB1M
- PCB-ASSY-IPB5-100
- ROBOT CABLE,MW
- CARRIAGE FFC,MW
ditto
ditto
Reference to
Check/Replace
Part
Parts
 5.5.58
 5.5.58
 5.5.58
 5.5.58
 5.5.58
 5.5.58
 5.5.58
 5.5.59
 5.5.59
 5.5.59
 5.5.59
 5.5.59
 5.5.59
 5.5.59

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents