(LCIS model)
CLOSE THE
RESERVOIR DRAWER
<Description>
The reservoir drawer is open.
If the error does not disappear after closing the reservoir drawer, there may be a problem with the
sensor.
<Action>
Check the Items to be Checked on the table below, and perform the actions starting from the top
until the problem is solved.
No
Items to be Checked
1
Drawer connectors
2
CABLE(LCISWei-Sen)-ASSY(MW)
replacement
3
CABLE(LCISWei-Sen-IF)-ASSY(MW)
replacement
OKI Data Infotech Corporation CONFIDENTIAL
Chapter 5 Troubleshooting (Engine Section and USB Controller Section)
Check that the connectors are correctly in contact when
the drawer is closed.
Replace the harness if the connectors are damaged or
do not contact properly.
Replace the harness if the connectors are damaged or
do not contact properly.
Action
5-25