<Errors related to media jams>
Panel Message
MEDIA JAM ERROR
LIFT THE LEVER
MEDIA JAM ERROR
LIFT THE LEVER
<Media-related errors>
Panel Message
LIFT THE LEVER AND
LOAD THE MEDIA
LOAD MEDIA
Error Description
Foreign matter on the
- Check that there is
1
carriage path prevents
no foreign matter
the printer from driving
on the platen.
the carriage correctly.
- Check that all the
four leveling feet
are properly in
contact with the
floor.
- Restart the printer.
The media is not
- Reinstall the
2
detected correctly.
media.
- Check that the
media edges are
placed within the
gradations.
- Check if the
problem also
occurs with other
types of media.
- Restart the printer.
Error Description
There is no more
- Install a new media
media.
roll.
- Check that the
media edges are
placed within the
gradations.
- Check if the
problem also
occurs with other
types of media.
- Restart the printer.
The media cannot be
- Reinstall the
detected.
media.
- Check that the
media edges are
placed within the
gradations.
- Check if the
problem also
occurs with other
types of media.
- Restart the printer.
Chapter 5 Troubleshooting (Engine Section and USB Controller Section)
Service Engineer Inspection
(For inspection criteria, see
User Solution
Reference to Check/Replace
- Check that the Y motor cables
are connected correctly.
- Check that the linear encoder
connectors are connected
correctly.
- Check that the CARRIAGE
FFC,MW connectors are
connected correctly to both the
HCB1M and the IPB5.
- Check that the ROBOT
CABLE,MW connectors are
connected correctly.
- Check that the ENCODER
STRIP,MW is not soiled or
damaged.
- Check the SUS belt tension.
- Check the tension of the Y motor
timing belt.
- Check that the non-reflecting
tape on the platen is not soiled.
- Check that the edge sensor is
correctly installed and clean.
- Check that the edge sensor
connector is connected correctly.
- Check that the CARRIAGE
FFC,MW connectors are
connected correctly to both the
HCB1M and the IPB5.
- Check that the ROBOT
CABLE,MW connectors are
connected correctly.
Service Engineer Inspection
(For inspection criteria, see
User Solution
Reference to Check/Replace
- Check that the media output
sensor is correctly installed and
clean.
- Check that the media output
sensor connector is connected
correctly.
- Check that the
SWITCH(RollEnd)-ASSY
connector is connected correctly.
- Check that the media output
sensor is correctly installed and
clean.
- Check that the media output
sensor connector is connected
correctly.
- Check that the
SWITCH(RollEnd)-ASSY
connector is connected correctly.
OKI Data Infotech Corporation CONFIDENTIAL
Assumed
Replacement Part
Parts.)
- Y DRIVE
MOTOR,MW
- CABLE
ENCODER,MW
- ENCODER
STRIP,MW
- PCB-ASSY-ACT3
- PCB-ASSY-HCB1M
- PCB-ASSY-IPB5-100
- CARRIAGE
CABLE,MW
- ROBOT CABLE,MW
- DRIVING PULLEY
UNIT,MW
- CABLE(Y-MOT)-
ASSY(MW)
- Media detect and Line
sensor OKI Data
Infotech
- PCB-ASSY-ACT3
- PCB-ASSY-HCB1M
- PCB-ASSY-IPB5-100
- CARRIAGE
CABLE,MW
- ROBOT CABLE,MW
Assumed
Replacement Part
Parts.)
- Media detect and
Line sensor OKI Data
Infotech
- SWITCH(RollEnd)-
ASSY
- PCB-ASSY-ACT3
- PCB-ASSY-IPB5-100
- Media detect and
Line sensor OKI Data
Infotech
- SWITCH(RollEnd)-
ASSY
- PCB-ASSY-ACT3
- PCB-ASSY-IPB5-100
Reference to
Check/Replace
Parts
Reference to
Check/Replace
Parts
5-19