List Of I/O Signal Details - Mitsubishi MELSEC-Q Series User Manual

Positioning module with built-in counter function
Hide thumbs Also See for MELSEC-Q Series:
Table of Contents

Advertisement

3
SPECIFICATIONS AND FUNCTIONS
3.5.3
The details of each signal for the QD72P3C3 external device connector are shown below.
Signal name
Pin No.
Zero signal
A14
Zero signal common
A13
Near-point dog signal
A10
Upper limit signal
A8
Lower limit signal
A6
A9
Common
A7
A5
Deviation counter clear
A12
Deviation counter clear
A11
common
Pulse output F
A4
Pulse output R
A2
A3
Pulse output common
A1
Phase A pulse input
A20
24V
Phase A pulse input 5V A19
Phase A common
A18
Phase B pulse input
A17
24V
Phase B pulse input 5V A16
Phase B common
A15

List of I/O signal details

Symbol
(Negative logic is selected by external I/O signal logic selection)
•Input the zero signal for machine OPR control.
Use the encoder's zero signal and so on.
B14
PG0
•Use this signal when "
OPR complete is input from an external device.
•The zero signal is detected at turning from OFF to ON.
B13
PG0 COM •Common for zero signal
•This signal is used for detecting the near-point dog during machine OPR
B10
DOG
control.
•The near-point dog signal is detected at turning from OFF to ON.
•Input this signal from the limit switch, which is set to the stroke upper
B8
FLS
limit position.
•Turning OFF this signal stops positioning.
•Input this signal from the limit switch, which is set to the stroke lower
B6
RLS
limit position.
•Turning OFF this signal stops positioning.
B9
•Common for near-point dog signal, upper limit signal, and lower limit
B7
COM
signal
B5
•This signal is output during machine OPR control.
•The output time of the deviation counter clear is set in "
counter clear signal input time".
B12
CLEAR
•Use the drive unit that can reset the droop pulse amount in the internal
deviation counter when the QD72P3C3 turns this signal ON.
(Note) The deviation counter clear is a signal output by the QD72P3C3
during machine OPR control. It cannot output randomly.
CLEAR
B11
•Common for deviation counter clear
COM
•This signal is used to output command pulses to the open collector
B4
PULSE F
compatible unit.
CW/CCW mode: CW, PULSE/SIGN mode: PULSE
•This signal is used to output command pulses to the open collector
B2
PULSE R
compatible unit.
CW/CCW mode: CCW, PULSE/SIGN mode: SIGN
B3
PULSE
•Common for pulse output F and pulse output R
B1
COM
B20
CHA_24V •Phase A pulse input for 24V
B19
CHA_5V
•Phase A pulse input for 5V
B18
CHA COM •Common for phase A pulse
B17
CHB_24V •Phase B pulse input for 24V
B16
CHB_5V
•Phase B pulse input for 5V
B15
CHB COM •Common for phase B pulse
3.5 Specifications of I/O Interfaces with External Device
Signal details
OPR method" is the stopper 3 and the
Pr.10
Pr.10
3.5.3 List of I/O signal details
1
2
3
4
5
Deviation
Pr.7
6
7
8
3
- 17