11
AUXILIARY FUNCTION
11.4

Software Stroke Limit Function

This function sets the upper/lower limits of workpiece movable range using the address
(
movable command if it is issued to out of the setting range.
Set the upper/lower limits of the workpiece movable range in "
upper limit value"/"
(1) Movable region
Emergency stop
limit switch
11
- 6
11.4 Software Stroke Limit Function
Current feed value) established by the machine OPR control and disables the
Md.1
• This function works for "
address/movement amount" (value of current value change).
• This function works at operation start and during operation.
Software stroke limit lower limit value".
Pr.2
The following figure shows the workpiece movable range when the software stroke
limit function is used.
Software stroke limit
lower limit
(Machine movement range)
OP
Figure 11.3 Workpiece movable range
Current feed value" and "
Md.1
Positioning
Da.5
Software stroke limit
Pr.1
Software stroke limit
upper limit
Emergency stop
limit switch